VW Passat repair


+ 1. Ekspluatatsiiya of the car
+ 2. Maintenance
+ 3. Engines
+ 4. Cooling system
+ 5. Power supply system
+ 6. System of ignition
+ 7. Coupling
+ 8. Transmission
+ 9. Drive of forward wheels
+ 10. Suspension brackets
+ 11. Steering
+ 12. Brake system
+ 13. Wheels and tires
- 14. Systems of heating, ventilation and conditioning
   14.1. Technical characteristics
   14.2. General information
   14.3. Air conditioning system with the circulating coolant
   14.4. Precautionary measures at service of air conditioning system
   + 14.5. Search of malfunctions
   14.6. Filling of the conditioner with coolant
   14.7. Search and elimination of malfunctions in systems of heating and conditioning
   14.8. Airdistributing box
   14.9. Fan
   14:10. Cover of airinflow and vacuum system
   14:11. Air-receiver
   + 14:12. Heater fan
   - 14:13. Cables of management
      14.13.1. Order of accession of cables to the control panel
      14.13.2. Adjustment
      14.13.3. Check
   + 14:14. Air conditioning system units
   + 14:15. Basic provisions on service of the conditioner
+ 15. Electric equipment
+ 16. Body
+ 17. Electric circuits



ed639308




Repair Volkswagen Passat B3-B4/Passat B3-B4>> Systems of heating, ventilation and conditioning>> Cables of management>> Adjustment
After accession of cables to the control panel and installation of the control panel into place adjust cables.
Regulate cables in the following order.
Cable of control of the gate of the air duct of heating of legs and windshield:
– transfer the handle of distribution of a stream of air to situation "DEFROST";
– connect a cable to the lever on a casing;

Fig. 14.15. Installation/adjustment of a cable of control of the gate of the air duct of heating of legs and windshield: 1 – cable of control of the gate of the air duct of heating of legs and windshield


– transfer the lever to extreme situation ( fig. 14.15 );
– having pressed the lever in the direction of an arrow and holding it, establish a lock bracket.
Cable of control of the distributive gate:
– transfer the handle of distribution of a stream of air to the provision of "VENT";
– connect a cable to the lever on a casing;

Fig. 14.16. Installation/adjustment of a cable of control of the distributive gate: 1 – cable of control of the distributive gate


– transfer the lever to extreme situation ( fig. 14.16 );
– having pressed the lever in the direction of an arrow and holding it, establish a lock bracket.